Skip to content
Speedymason, thin brick simplified
Menu

Install guide: Wood studs with plywood, OSB or gypsum sheathing

Thin brick on a wood frame wall.

On a wood frame wall, Speedymason Brick Lath goes over exterior-grade sheathing and the air and water barrier, fastened with ring shank nails or screws every 8 inches on center. The panel holds a full bed of polymer-modified thin set, so there is no wire lath and no scratch coat. 5/8 inch plywood or OSB is preferred; 7/16 inch is the minimum.

Fasteners

  • Collated stainless-steel ring shank nails or galvanized roofing nails, ring shanked, at least 1-3/4 inch long
  • Or #6 or #8 wafer or pancake head screws, galvanized, stainless or coated for exterior use
  • Fasteners must penetrate the studs at least 1 inch
  • Every 8 inches on center on the fastener strips

Sheathing and substrate

  • 5/8 inch plywood or OSB preferred; panels need not break on studs
  • 7/16 inch plywood or OSB is the minimum; panels must break on studs
  • 5/8 inch gypsum sheathing is acceptable; break on studs and screw between studs
  • In hurricane zones, 5/8 inch structural sheathing is required

Step by step

The sequence.

  1. 1Install the building wrap, sealer or fluid-applied barrier over the sheathing to code. The dimples on the back of the panel act as a watershed over it.
  2. 2Build a starter panel and set the layout from it. Install with the groove facing down and the tongue fully in the groove.
  3. 3Butt panels end to end with no more than 1/8 inch and no less than a dime width between them, and stagger the seams so no two panels end on the same line.
  4. 4Fasten on the fastener strips every 8 inches on center. Break the butt ends on a stud when the sheathing is thinner than 5/8 inch.
  5. 5Use Speedymason outside corner panels at every exterior corner, screwed through the reinforced angle brackets (12 screws per corner).
  6. 6Mix polymer-modified thin set. Trowel it over the guide legs, which meter the depth, or fully back-butter each brick. The brick can be any thin brick from any maker: extruded, saw cut, concrete or manufactured, or glass and ceramic tile in brick sizes.
  7. 7Angle each brick onto the bed-joint leg and press in from the bottom until thin set squeezes around it.
  8. 8Bag the joints between the bricks with grouting/pointing mortar, let it set to the feel of wet beach sand, and strike. Do not bag with thin set.
  9. 9Clean no sooner than 5 days and no later than 10 days after grouting, with the brick maker's cleaner. Seal with the sealer the brick maker specifies.
Wall section showing mortar locked around Speedymason Brick Lath

Watch for

  • Control joints every 15 feet, or as the architect or code calls out
  • Flash and caulk openings and terminations to code or the Speedymason detail sheets
  • Any thin brick from any maker, 3/8 to 1-1/2 inch thick: extruded, saw cut, concrete or manufactured thin brick, and glass or ceramic tile in brick sizes

The two materials

Polymer-modified thin set
The setting bed the brick is pressed into. Polymer modified, meeting ANSI A118.4 shear bond, ASTM C1714 and ASTM C270 Type S, per the guide specification. Stone Lath and Ultra-Speed take a specialty polymer-modified thin set.
Grouting/pointing mortar
Type S or Type N mortar, bagged into the joints between the bricks after they are set, then struck. Never thin set in the joints, and no joint mortar at all on Ultra-Speed, which is dry stacked.

Products Speedymason has approved are listed in the installation guide.

Questions

Asked on the jobsite.

Do I need metal lath or a scratch coat on a wood frame wall?

No. Speedymason Brick Lath replaces the wire lath, and the polymer-modified thin set is troweled straight onto the panel over the guide legs. The scratch coat step is gone.

What goes between the sheathing and the panel?

A code-approved air and water barrier: building wrap, sealer or a fluid-applied membrane. The dimples on the back of the panel drain over it. A factory-applied rainscreen is available where the project calls for one.

How far apart are the fasteners?

Every 8 inches on center on the fastener strips for exterior work. Interior work over studs is every 16 inches.

Installation guide (PDF) Install videos

Other walls

More install guides.

Next step

A wall that is not on this list?

Send a photo or a section and we will tell you how the panel goes on.